Setting up the G3 for CPU communication
Once the PLC is setup, all required information is available to configure the G3. Start Crimson 2.0 software
and create a new database (via File>New). Select the device you are programming. In this example, we will be
using a G306 HMI.
Enter the “Communications” module and follow the steps as shown in figure 5:
1. Select the Ethernet port.
2. Define the port mode. In this example, it will be Manual configuration.
3. Enter the G3 IP address if required. Here 192.168.200.10.
Figure 5
Once the Ethernet port is activated, the communication driver has to be defined as follows (Figure 6):
1. Select the Protocol 1 under Ethernet.
2. On the right hand pane, click Edit to select a driver.
3. In the popup window, under Manufacturer, select Siemens.
4. Then, under Driver, select S7 300 TCP/IP Master and click OK.
A device called PLC1 should then appear under the Protocol 1. This device represents the Siemens PLC and
can be renamed to fit your application.
1
2
3