Communication Services
4-8
SIMATIC 505 PROFIBUS-FMS CP User Manual
4.3 FMS Services
Before
you configure an FMS communication job, you must first define an
FMS connection using the COM5434 Configurator
. To establish a successful
connection, the services of the communication partners must be matched. As
requester
, you specify the services that you expect from the partner device.
As responder
, you specify the services you provide for the partner device.
NOTE:
The software generates an “Object Dictionary” that contains the
names and index numbers of the FMS variables you configure. To enable
partners to access variables by name, enable the Get Object Dictionary
service when configuring an FMS connection. (Refer to Figure 5-15.)
T
o define an FMS connection using the COM5434 Configurator
, follow the
steps described in Section 5.6.
The FMS CP module acts as a client (initiator) for the following FMS jobs:
Read – reads data from a data area of the communication partner
specified by a name or index.
W
rite – transfers data from a specified local data area to a data area of
the communication partner
.
Information Report – allows unconfirmed transmission of variables by
an FMS server
.
Status – the partner device sends logical and physical status
information that may include the following items: whether
communication is possible, for example, CPU is in RUN; physical
status of CPU, for example, maintenance is required. (Refer to
Section A.3 for more information about Status request responses.)
Identify – the partner device sends three ASCII strings that provide
the following information: name of the device vendor
, name of the
device model, and revision or version of the device. (Refer to Section A.3
for more information about Identify request responses.)
The FMS job types are described and illustrated in Figure 4-4.
These coordinated client jobs must be configured in the client module. T
o
configure an FMS job, follow the steps described in Section 5.9.
The server station must also be configured to coordinate with the client
station. Y
ou must configure coordinating FMS connections for all FMS job
types, and FMS variables for Read and W
rite jobs in the server station.
FMS Connections
FMS
Communication
Job T
ypes
FMS Server
Functions
Seitenansicht 58