Model Designations and Specifications UMSITRPDS3-1
November 2010
9-14
Additional Model 7MF4333 Selections and Data*
Order Code
Transmitter with mounting bracket of:
- steel
A01
- stainless steel
A02
Process flange O-ring (instead of FPM (Viton®)) of:
- PTFE (Teflon®)
A20
- FEP (with silicone core, approved for food)
A21
- FFPM (Kalrez®, compound 4079)
A22
- NBR (buna N)
A23
Plug: Han 7D (metal, gray)
A30
Plug: Han 8U (instead of Han 7D)
A31
Sealing screws (1/4-18 NPT) with valve in same material as process flange
A40
Cable sockets for M12 connectors (metal)
A50
Inscribing of rating plate (instead of German):
- English
B11
- French
B12
- Spanish
B13
- Italian
B14
- English, pressure units in inH
2
O or psi
B21
Manufacturer test/calibration certificate M to DIN 55350, Part 18, and ISO 8402
C11
Acceptance test certificate to EN 10204-3.1
C12
Factory certificate to EN 10204-2.2
C14
“Functional Safety (SIL)” certificate
C20
Setting of the upper limit of output signal limit to 22.0 mA
D05
Manufacturer’s declaration according to NACE
D07
Type of protection IP 68
D12
Digital indicator alongside the input keys
D27
Supplied with oval flange
D37
Use in or on Zone 1D/2D
E01
Use on Zone 0
E02
Oxygen cleaning application, 160 bar a (2320 psi a) maximum, for oxygen measurement and inert liquid
E10
Explosion proof, intrinsic safety to INMETRO (Brazil)
E25
Explosion proof, intrinsic safety to NEPSI (China)
E55
Explosion protection, explosion proof to NEPSI (China)
E56
Explosion proof, Zone 2 to NEPSI (China)
E57
Interchanging of process connection sides
H01
Vent on side for gas measurement
H02
Process flange:
- Hastelloy
K01
- Monel
K02
- Stainless steel with PVDF insert, PN 10 (MWP 145 psi) maximum, temperature of
medium 90°C (194°F) maximum
K04
Measuring range to be set, specify in plain text:
Y01: 0 to ... mbar, psi, kPa, MPa, ... (27 characters maximum)
Y01
Tag number/description, 16 characters maximum, specify in plain text
Y15
Tag message, 27 characters maximum, specify in plain text
Y16
Entry of HART address (Tag), 8 characters maximum, specify in plain text
Y17
Setting of pressure indication in pressure units, specify in plain text: mbar, psi, kPa, MPa...
Y21
Setting of pressure indication in non-pressure units: l/min, m
3
/h, m, USgpm...
Y22+Y01
Only Y01, Y21, Y22, Y25 and D05 can be factory preset.
* Add “-Z” to model number and specify Order Code(s).