45
Specifi cations
Absolute
ECN 1113 ECN 1123 EQN 1125 EQN 1135
Interface
EnDat 2.2
Ordering designation EnDat01 EnDat22 EnDat01 EnDat22
Position values/rev 8 192 (13 bits) 8 388 608 (23 bits) 8 192 (13 bits) 8 388 608 (23 bits)
Revolutions – 4 096 (12 bits)
Elec. permissible speed/
Deviation
2)
4 000 min
–1
/± 1 LSB
12 000 min
–1
/± 16 LSB
12 000 min
–1
(for contin. position value)
4 000 min
–1
/± 1 LSB
12 000 min
–1
/± 16 LSB
12 000 min
–1
(for contin. position value)
Calculation time t
cal
Clock frequency
i 9 μs
i 2 MHz
i 7 μs
i 8 MHz
i 9 μs
i 2 MHz
i 7 μs
i 8 MHz
Incremental signals 1 V
PP
1)
– 1 V
PP
1)
–
Line count 512 – 512 –
Cutoff frequency –3 dB j 190 kHz – j 190 kHz –
System accuracy
± 60“
Electrical connection
Via PCB connector,
15-pin
Via PCB connector,
15-pin
3)
Via PCB connector,
15-pin
Via PCB connector,
15-pin
3)
Voltage supply 3.6 V to 14 V DC
Power consumption
(maximum)
3.6 V: i600 mW
14 V: i 700 mW
3.6 V: i 700 mW
14 V: i 800 mW
Current consumption
(typical)
5 V: 85 mA (without load) 5 V: 105 mA (without load)
Shaft
Blind hollow shaft 6 mm with positive fi t element
Mech. permiss. speed n 12 000 min
–1
Starting torque i 0.001 Nm (at 20 °C) i 0.002 Nm (at 20 °C)
Moment of inertia of rotor Approx. 0.4 · 10
–6
kgm
2
Permissible axial motion of
measured shaft
± 0.5 mm
Vibration 55 to 2 000 Hz
Shock 6 ms
i 200 m/s
2
(EN 60 068-2-6)
i 1 000 m/s
2
(EN 60 068-2-27)
Max. operating temp.
115 °C
Min. operating temp.
–40 °C
Protection EN 60 529 IP 40 when mounted
Weight
Approx. 0.1 kg
1)
Restricted tolerances Signal amplitude: 0.80 to 1.2 V
PP
Asymmetry: 0.05
Amplitude ratio: 0.9 to 1.1
Phase angle: 90° ± 5° elec.
2)
Velocity-dependent deviations between the absolute and incremental signals
3)
With connection for temperature sensor, evaluation optimized for KTY 84-130
Functional safety available for ECN 1123 and EQN 1135. For dimensions and specifi cations, see the Product Information document.
Antriebsgeber_en_2013.indd 45 12.11.2013 06:55:13