Distributed Use of SIMATIC FS600 Laser
Scanner in Category 3 / SIL 2
Entry ID: 21330889
A&D Safety Integrated Page 15/51 AS-FE-I-010-V20-EN
Copyright © Siemens AG 2007 All rights reserved
21330889_as_fe_i_010_v20_en_lscanner.doc
Configuration software/tools
Component Type MLFB / Order information No. Manufacturer
SIMATIC STEP 7 V5.4 + SP1 6ES7810-4CC07-0YA5 1
SIMATIC Distributed Safety V5.4 + SP3 6ES7833-1FC01-0YA5 1
LS4soft V1.12 Delivered with laser scanner SIMATIC FS600 1
SIEMENS AG
4 Setup and Wiring
In order to set up and wire the safety functional example, it is absolutely
necessary to consider the following note:
NOTICE
In order to meet the requirements of category 3 / SIL 2, it is
obligatory for certain actuators (e.g. contactor) to read back the
process signal to the actuator.
Read-back is not implemented in this safety functional example. The
actuator is an indicator light simulating a machine. When using
different actuators, the feedback circuits have to be integrated and
evaluated by the user. Safety functional example 7 provides a
detailed description of “Read back”.