Distributed Use of SIMATIC FS600 Laser Scanner in
Category 3 / SIL 2
Entry ID: 21330889
A&D Safety Integrated Page 49/51 AS-FE-I-010-V20-EN
Copyright © Siemens AG 2007 All rights reserved
21330889_as_fe_i_010_v20_en_lscanner.doc
8.2 Assessment of "Detect"
8.2.1 Evaluation according to EN 62061
Result:
Result Explanation
SILCL 2
PFH
D
8.96 * 10
-8
Information of the manufacturer SIEMENS AG
8.2.2 Evaluation according to EN ISO 13849-1: 2006
Result:
Result Explanation
PL ---
Average probability of a hazardous
failure per hour
---
An evaluation according to
EN ISO 13849-1: 2006
is not available.