Distributed Use of SIMATIC FS600 Laser
Scanner in Category 3 / SIL 2
Entry ID: 21330889
A&D Safety Integrated Page 5/51 AS-FE-I-010-V20-EN
Copyright © Siemens AG 2007 All rights reserved
21330889_as_fe_i_010_v20_en_lscanner.doc
2 Automation Function
2.1 Description of the functionality
2.1.1 Foreword
Application areas
The laser scanner SIMATIC FS600 is used for hazard protection. The laser
scanner, aligned horizontally in most cases, monitors the presence of
persons in the protected zone.
When using the laser scanner SIMATIC FS600, access to the hazardous
location must only be possible through the protected zone. A safe distance
must be kept between protected zone and hazardous location. The
distance is calculated according to the formulas in the specific machine
related European C standards or in the general B1 standard EN 999.
The relevant regulations of machine safety in Europe apply for the use of
distance scanners (e.g. laser scanner SIMATIC FS600), in particular:
machinery directive 98/37/EC
work equipment directive 89/655/EEC
Operating principle of the laser scanner SIMATIC FS600
The laser scanner SIMATIC FS600 is a distance scanner. It sends very
short laser pulses and measures the time until the pulse hits an object, as
well as its remission (diffuse reflection of a beam by a non-reflecting
surface) to the receiver in the laser scanner. The device uses this time to
calculate the distance between object and laser scanner. The sensor unit of
the laser scanner SIMATIC FS600 rotates and sends/receives a laser pulse
after each 0.36°. A circular sector of up to 190° is scanned in the center of
which the laser scanner is located.