FAQ (Frequently Asked Questions)
DP Base Programming Interface for CP 5613/CP 5614
C79000-G8976-C108-01
215
5.5 FAQs Miscellaneous Programming Questions
Can groups of slaves be used for hardware events?
You can do this yourself with the software tools, for example: at the start of each
cycle, activate the hardware events of all slaves in the group and, as soon as an
event occurs, deactivate them all again until the end of the cycle.
What names are given to the modules when they are installed?
The modules are given the names "CP5613_5614_1", "CP5613_5614_2" etc. by
the driver.
What differences are there in the user program for a CP 5614 and a CP 5613?
With a CP 5613, the "DPS_open" call returns the message that no slave exists;
see Section 4.2.2.
How can I use the CP 5613 or CP 5614 with a real-time kernel in Windows NT
without having to port all the drivers etc.?
Implement the CP startup and log off in Windows NT. In the meantime, operate the
CP in the real-time kernel only by accessing the process image. The alarm used
and also data are entered in the structure "info_watch.pci" in the process image
each time the Windows NT driver is started (see header file "dp_5613.h"). A
Windows NT user program can read this from here and pass it on to a real-time
kernel.
Who can I contact if I have problems?
Read the chapter "Where to Get Help" in the Installation Instructions for the
product.
Further information for programmers is also available from the following address: