SINAMICS G120
Inverter chassis units 0.37 kW to 132 kW (0.5 hp to 200 hp)
PM240 Power Modules
3/31
Siemens D 11.1 · 2008
3
■
Technical specifications (continued)
Line voltage
380 … 480 V 3 AC
PM240 Power Modules
Without integrated line filter 6SL3224-
0BE31-1UA0
6SL3224-
0BE31-5UA0
6SL3224-
0BE31-8UA0
6SL3224-
0BE32-2UA0
6SL3224-
0BE33-0UA0
With integrated line filter 6SL3224-
0BE31-1AA0
6SL3224-
0BE31-5AA0
6SL3224-
0BE31-8AA0
6SL3224-
0BE32-2AA0
6SL3224-
0BE33-0AA0
Output current at 400 V 3 AC
• Rated current I
rated
1)
A 32 38 45 60 75
• Base load current
I
L
1)
A 32 38 45 60 75
• Base load current
I
H
2)
A 26 32 38 45 60
•
I
max
A 52 64 76 90 124
Rated power
• based on I
L
kW (hp) 15 (20) 18.5 (25) 22 (30) 30 (40) 37 (50)
• based on
I
H
kW (hp) 11 (15) 15 (20) 18.5 (25) 22 (30) 30 (40)
Rated pulse frequency
kHz
4 4 4 4 4
Efficiency
!
> 0.97 > 0.97 > 0.97 > 0.97 > 0.97
Power loss
kW
0.4 0.44 0.55 0.72 1
Cooling air requirement
m
3
/s 0.055 0.055 0.055 0.055 0.055
Sound pressure level
L
pA
(1 m)
dB < 60 < 60 < 60 < 61 < 60
24 V DC power supply
for Control Unit
A
1 1 1 1 1
Rated input current
3)
• with line reactor
A 33 40 47 63 78
• without line reactor
A
39 46 53 72 88
Length of cable to braking resistor,
max.
m
15 15 15 15 15
Line supply connection
U1/L1, V1/L2, W1/L3
Screw terminals M6 screw studs M6 screw studs M6 screw studs M6 screw studs
• Conductor cross-section
mm
2
2.5 … 10 10 … 35 10 … 35 10 … 35 10 … 35
Motor connection
U2, V2, W2
Screw terminals M6 screw studs M6 screw studs M6 screw studs M6 screw studs
• Conductor cross-section
mm
2
2.5 … 10 10 … 35 10 … 35 10 … 35 10 … 35
DC link connection,
connection for the braking resistor
DCP/R1, DCN, R2
Screw terminals M6 screw studs M6 screw studs M6 screw studs M6 screw studs
• Conductor cross-section
mm
2
2.5 … 10 10 … 35 10 … 35 10 … 35 10 … 35
PE connection
On housing with
M5 screw
On housing with
M6 screw
On housing with
M6 screw
On housing with
M6 screw
On housing with
M6 screw
Motor cable length
4)
, max.
• Shielded
m 50 50 50 50 50
• Unshielded
m
100 100 100 100 100
Degree of protection
IP20 IP20 IP20 IP20 IP20
Dimensions
• Width mm 189 275 275 275 275
• Height
- without integrated filter mm 334 419 419 419 499
- with integrated filter mm 334 512 512 512 635
• Depth
- without Control Unit mm 185 204 204 204 204
- with Control Unit mm
250 260 260 260 260
Frame size
FSC FSD FSD FSD FSE
Weight, approx.
• without integrated filter
kg 7 13 13 13 16
• with integrated filter
kg
7 16 16 16 23
1
The rated output current I
rated
and the base load current I
L
are based on
the loading for light overload (LO).
2)
The base load current
I
H
is based on the loading for high overload (HO).
3
The input current depends on the motor load and line impedance. The input
currents apply for a load representing the rated power (based on
I
rated
) for a line impedance corresponding to u
K
= 1 %. These current values
without line reactor are quoted on the rating plate of the Power Module.
4)
Max. motor cable length 25 m (shielded) for PM240 Power Modules with
integrated line filter to maintain the limit values of EN 61800-3 Category C2.
Kommentare zu diesen Handbüchern