Configuration of a 3-phase
monitoring function
Phase
failure
Phase
imbalance,
voltage
Direction
of rotation
L1
L2
L3
M
contactor
3UG4
monitoring
relay
3UG Monitoring Relays
for line, single-phase voltage
and insulation monitoring
The new 3UG4 monitoring relays provide a
maximum degree of protection for machines,
plants and systems. This means that line and
voltage faults are detected early and the
appropriate response is initiated before
more
significant damage can occur.
Measured quantity Possible plant or system fault
Phase sequence Direction of rotation of the drive
Phase failure A fuse has blown
Control supply voltage has failed
Single-phase operation of a motor with corresponding overheating
Phase dissymmetry Motor overheating as a result of non-symmetrical voltages
or phase failure
Line supplies with non-symmetrical load are detected
A phase failure is detected in spite of regenerative feedback
Undervoltage Motor draws an increased current and in turn overheats
A device is undesirably reset
Detection of line supply dips, especially when supplied from a battery
Threshold value switch for analog signals 0 to 10 V
Overvoltage A plant is protected against destruction due to
supply overvoltages
A plant or system switches-in above a certain voltage
Threshold value switch for analog signals 0 to 10 V
Insulation monitoring The insulation resistance for non-grounded plants and systems is monitored
Your advantages:
Due to the wide voltage range it can be used on all line
supplies around the world – from 160 V to 690 V – without
an auxiliary voltage
Can be set to overrange, underrange and window
monitoring
Freely parameterizable delay times and reset functions
Reduced width for all versions for line and voltage monitoring
For the digital versions, the actual value and fault type are
displayed
Automatic rotation direction correction by differentiating
between line faults and incorrect phase sequence
All versions have removable terminals
All versions have either screw terminals or alternatively
innovative spring-loaded terminals
Applications:
The applications are listed in the following table. These tables
indicate the various equipment/system conditions that can be de-
tected
using the monitoring parameters.