AC75 AT Command Set
2.9 AT+CFUN
s
AC75_ATC_V01.002 Page 45 of 569 10/30/06
Confidential / Released
Quit: ME exits SLEEP mode.
Temporary: ME becomes active temporarily for the duration of the event and the mode-specific follow-up time
after the last character was sent or received on the serial interface.
No effect: Event is not relevant in the selected SLEEP mode. The ME does not wake up.
Table 2.3: Wake-up events in NON-CYCLIC and CYCLIC SLEEP modes
Event Selected mode:
<fun>=0
Selected mode:
<fun>=7 or 9
Ignition line No effect No effect
/RTS0 or /RTS1 activation Quit Mode 7: No effect (RTS is only
used for flow control)
Mode 9: Temporary
Unsolicited Result Code (URC) Quit Temporary
Incoming voice or data call Quit Temporary
Any AT command (incl. outgoing
SMS, voice or data call)
From Java: Yes
Without Java: Not possible (UART
disabled)
Temporary
Incoming SMS (AT+CNMI is set to
0,0 (this is the default setting)
No effect No effect
Incoming SMS (AT+CNMI is set to
1,1)
Quit Temporary
GPRS data transfer From Java: Yes
Without Java: Not possible (UART
disabled)
Temporary
RTC alarm line Quit Temporary
AT+CFUN=1 From Java: Yes
Without Java: Not possible (UART
disabled)
Quit
Java terminates Quit Temporary