Data Type Identification
A-4
TIWAY I Gateway User Manual
A.3 TIWAY I Gateway Specifications
T
able A-3
TIWAY
I Gateway Featur
es
TIWAY I Gateway Features Before Rel. 1.3 Release 1.3
User-defined commands for IDT products
n
Message resynchronization after timeout
n
Selectable coil type (Y or C)
n
IDT data addressing scheme
n
Command support:
Read inputs
Read outputs
Read holding register
Read input register
Write holding register
Read exception status
Loopback test
Get communications event counter
Get communications event log
Write multiple coils
Write multiple holding registers
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
T
able A-4
TIWAY
I Gateway Physical and Envir
onmental Specifications
Network Communication 1 channel per unit
Compatible PLCs
5TI, TI520/TI530, TI520C/TI530C, TI530T
, PM550/C, TI560,
TI565, TI560T, TI565T
Host port interface RS-232-C/423
Maximum cable length 25,000 feet (Local Line); 50 feet (RS-232-C/423)
Network port interface RS-232-C/423 or Local Line
Data link protocol HDLC with 16-bit cyclic redundancy error checking (CRC–CCITT)
Network data rates 1
10 bps – 1
15.2 kbps
Host port data rates 1
10 bps – 19.2 kbps
Modem types supported Asynchronous/synchronous
Half/full duplex
Multi-drop/point-to-point
Network undetected bit error rate
6 x 10
–13
(calculated) with premium cables
Unit size
9.5″
H x 4.0
″
W x 7.5
″ D
Unit power consumption
20 V
A maximum
Operating temperature
0 to 60
°
C (32 to 140
°F)
Storage temperature
–40 to +85
°
C (–40 to 185
°F)
Operating humidity range 0% to 95% relative humidity, noncondensing
Agency approvals
ULr Listed
CSA Certified
Factory Mutual Research: Class I, Div. 2 hazardous locations