3 Removing and fitting housing
3–56 Section 3 © Siemens VDO Trading GmbH TU00-1318-0200302
3.13 Replacing carriage contact
Fig. 3-41 Replacing carriage contact
Procedure
when removing
Unsolder connection cables (3) and (4) on the back of the frame (5) and suck
any solder out with a vacuum pump.
Disengage contact springs (1) and (2) and remove them.
Procedure
for installing
Insert contact spring (2).
Insert contact spring (1).
Solder connection cables (3) and (4).
1 Contact spring 4 Connection cable
2 Contact spring 5 Back of frame plate
3 Connection cable
1
2
5
3
4
Note
When inserting contact springs (1) and (2) ensure that they engage securely.