Technical Product Manual
Fault analysis and repairs 1318
3 Removing and fitting housing
Section 3: Removing and fitting housing • Edition 12/2005
TU00-1318-0200302 © Siemens VDO Trading GmbH Section 3 3–73
3.16.9 Plug unit and trough connector
3.16.9.1 Fitting plug unit/ data output and trough connector to v board
Fig. 3-56 Fitting plug unit and trough connector
Procedure
Fit the plug unit (2) into the v board:
Engage catch lugs (3) and (4) into recesses (5) and (6).
Place the sealing ring (1) onto the plug unit (2).
Fit the plug unit (11) into the v board:
Engage catch lugs (10) and (12) and pin (13) into recesses (7), (8) and (9).
1 Sealing ring 8 Recess
2 Plug unit 9 Recess
3 Catch lug 10 Catch lugs
4 Catch lug 11 Trough connector
5 Recess 12 Catch lug
6 Recess 13 Pin
7 Recess
9
8
7
10
11
1
2
13
1
2
3
4
56
to 01.94
Seitenansicht 164