Technical Product Manual
Fault analysis and repairs 1318
6 Additional equipment
Section 6: Additional equipment • Edition 12/2005
TU00-1318-0200302 © Siemens VDO Trading GmbH Section 6 6–13
6.4.2 Control
Level 1: – Current supplied to stylus magnet (5) via connector "D1".
– No current supplied to stop magnet (7).
Level 2: – Current supplied to stylus magnet (5) via connector "D1".
– Current supplied to stop magnet (7) via connector "D2".
6.4.3 Adjusting additional stylus
Fig. 6-10 Setting drive parts
Modified since 02.90
+ The yoke (9) and coils (10) and (11) have been reduced by 0.7 mm.
Procedure
– Set dimension B = 0.25 mm on the lugs (12) using a feeler gauge.
– Set dimension C = 0.6 mm +0.2 by moving coil (10).
– Push the lever (14) down up to the stop (13)in the direction of the arrow (c).
– Use the feeler gauge to set dimension D = 0.05 mm and put it between parts
(16) and (17).
– Push the coil (11) to the stop (13) in the direction of the arrow (d).
– Tighten screws (6) and (8). (See Fig. 6-9).
9 Yoke 14 Lever
10 Coil 15 Armature
11 Coil 16 Part
12 Lug 17 Part
13 Stop
15
d
17
c
13
14
C
12
B
A
B = 0.25
C = 0.6
+0.2
A = 11
Note
• The unit must be switched off when carrying out any adjustment work.
• The stylus lever of the working time stylus (1) and additional stylus (2) must
not impede each other. (See
Fig. 6-9)
• Magnets (5) and (7) can be set in the direction of the arrows (a) and (b) by
undoing screws (6) and (8). (See Fig. 6-9)
• The lever (14) must move freely in area (A).
• If the armature (15) reaches its maximum deflection, there must be an air
gap at position (E).