Command Description Comment
name [device name]
Assigns a value to the sysName MIB
variable.
Maximum of 255 charac-
ters. If you want to use
the name in WDS or re-
dundancy, the maximum
length is 32 characters.
location [location]
Assigns a value to the sysLocation
MIB variable.
Maximum of 255 charac-
ters.
contact [name]
Assigns a value to the sysContact
MIB variable.
Maximum of 255 charac-
ters.
ping [-c N]
<IP Address|name>
For connection test to partner.
-c (counter) for the number of IGMPs
Telnet only
password [admin|user]
[password]
Specifies a password for access to
the SCALANCE W744.
Maximum of 31 charac-
ters.
5.2.2 IP Settings Menu Command
Configuration
Here, you decide whether you will use a DHCP server or whether you want to as-
sign a fixed IP address to the SCALANCE W744. You can also set the IP address
of a router and the default TTL. The TTL (time to live) parameter specifies the
maximum number of routers passed through by a data packet before it is dis-
carded.
Syntax of the Command Line Interface
CLI\SYSTEM\IP>
Command Description Comment
dhcp [E|D]
Enable / disable DHCP server.
ip [IP address]
Specifies the IP address for the
SCALANCE W744.
When you enter a valid IP
address, enabled DHCP
is automatically disabled.
subnet [subnet mask]
Specifies the subnet mask.
gateway [IP address]
Specifies the IP address of the rou-
ter.
ttl [TTL value]
Sets the TTL (Time To Live) pa-
rameter.
Default value: 64