Command Description Comment
web [E|D]
Enable / disable configuration of the
SCALANCE W744 over Web Based
Management.
psu [E|D]
Enable / disable access to the
SCALANCE W744 with the Primary
Setup Tool. If this access option is
deactivated, configuration data can
only be read with the Primary Setup
Tool.
5.2.4 Restart Menu Command
Restart Button
Click this button to restart the SCALANCE W744. During a restart, the
SCALANCE W744 is reinitialized, the internal firmware is reloaded, and the
SCALANCE W744 runs a self-test. The entries that have been learned in the ad-
dress table of the SCALANCE W744 are deleted. You can leave the browser win-
dow open while the SCALANCE W744 restarts.
Restore Memory Defaults Button
Click this button to reset the configuration. The following parameters (protected de-
faults) are not restored:
IP address
Subnet mask
Gateway address
SSID
IP address of the default router
DHCP flag
System name
System location
System contact
Device mode
Country code