Siemens CP 1515 Betriebsanleitung Seite 51

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 104
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 50
Configuration Using Web Based Management and the Command Line Interface
Operating Instructions SCALANCE W 744-1PRO
C79000-G8976-C185-03
51
5.2.5 Event Config Menu Command
System Events of the SCALANCE W744
On this page, you specify how the SCALANCE W744 reacts to system events. You
can configure the reaction of the SCALANCE W744
-1PRO to the following events:
Startup of the SCALANCE W744
Change in the Ethernet status Link up / Link down.
Error in authentication.
Changing the power supply of the SCALANCE W744.
Evaluation of this event is only useful when using a redundant power supply.
Change in the error status
Reaction to System Events
The following alternatives are possible:
The SCALANCE W744 sends an E-mail.
The SCALANCE W744 writes an entry in the log file.
The SCALANCE W744 indicates an error (the error LED lights up).
By selecting the appropriate check boxes, you specify which events trigger which
reactions on the SCALANCE W744. With the check box in the Functions enabled
row, you enable or disable the sending of E-mails or triggering of SNMP traps.
Syntax of the Command Line Interface
For each of the four possible reactions E-mail, trap, log and fault, either E (En-
abled, setting is enabled) or D (Disabled, setting is disabled) must be entered as
the parameter. If, for example, an E-mail is sent when the SCALANCE W744 re-
starts (first parameter "CW") and an entry is made in the log table but neither a trap
nor an error is generated, the following command must be entered:
setec CW E D E D
Seitenansicht 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 103 104

Kommentare zu diesen Handbüchern

Keine Kommentare