Syntax of the Command Line Interface
CLI\SYSTEM\CPLUG>
Command Description Comment
initdef
Reinitializes the C-PLUG and copies
the default configuration to it.
All information is deleted.
initmem
Reinitializes the C-PLUG and copies
the configuration currently stored
internally to it.
All information is deleted.
bootfrom [MEMORY]
Displays the source medium from
which the configuration is currently
being read: C-PLUG or MEMORY.
The restart is performed automati-
cally.
If the C-PLUG was re-
moved, you must specify
that the configuration
must be read from inter-
nal memory.
If a C-PLUG is inserted,
the system or as attempts
to read the configuration
from it. The bootfrom
[MEMORY] command
then has no effect.