Configuration Using Web Based Management and the Command Line Interface
Operating Instructions SCALANCE W 744-1PRO
50 C79000-G8976-C185-03
There is no automatic restart. This allows you to enter data using Web Based Man-
agement before the restart. The changes take effect only after a restart.
In User mode, this button is not visible.
Restore Factory Defaults and Restart Button
Click on this button to restore the factory configuration settings. The protected de-
faults (see above) are also reset. The C-PLUG here is also reinitialized and format-
ted if it exists. An automatic restart is triggered.
Note
By resetting all the defaults, the IP address is also lost. The SCALANCE W744 can
then only be accessed using the Primary Setup Tool unless the IP address is ob-
tained over DHCP.
In User mode, this button is not visible.
Syntax of the Command Line Interface
CLI\SYSTEM\RESTARTS>
Command Description Comment
restart
Restarts the SCALANCE W744. The restart command can
be called from all menus,
however not using the
shortcut commands.
memreset
Resets the factory settings and trig-
gers a restart (the protected settings
are not deleted).
defaults
Resets the factory settings (the pro-
tected settings are also deleted).