Industrial Ethernet OSM/ESM Network Management
C79000-G8976-C137-08
7. If autonegotiation is disabled, you can set the transmission rate and duplicity of
the port in the Mode list box. If autonegotiation is active, these parameters are
automatically negotiated by the OSM/ESM and the connected DTE, see
Section 2.1.
8. You can enter the name of the port in the Port Name box.
9. Click the Set New Values button to enter the modified values.
Autonegotiation (the negotiation of the transmission rate and duplicity) is generally
started only when a device is connected or started up. If you click the
Start/Restart Autonegotiation button, you can start autonegotiation immediately.
Note
Do not deactivate autonegotiation if you want to use the autocrossover function
with the partner port.