4.2 Requirements
To access an OSM/ESM using WBM, the following requirements must be met:
Internet Browser
You require a PC with an Internet browser. As the Internet browser, we
recommend a Netscape Communicator, Version 4.7 or a Microsoft Internet
Explorer, Version 5.0 or higher.
Before your Internet browser will work with the OSM/ESM, you must make the
correct settings in the browser. For more information, refer to Appendix A of this
manual.
Address Settings
If you operate your OSM/ESM in the same subnet as your PC/Internet browser,
you must first make the following settings via the CLI (serial port of the
OSM/ESM):
S The IP address of the OSM/ESM. (The IP address can be set with the CLI
command ip <IP address> , see also Section 3.5). As an option, the IP
address can also be assigned automatically using a BOOTP server, see also
Section 2.13.
S The subnet address of the OSM/ESM (CLI command subnet < IP address>,
see also Section 3.5).
If your PC/Internet browser is in a different subnet from the OSM/ESM (subnets
connected by a router), you must also set:
S The default gateway of the OSM/ESM (CLI command gateway < IP address>
).
As an option, these parameters can also be loaded from a BOOTP/DHCP
server.