Important OSM/ESM Functions
2-4
Industrial Ethernet OSM/ESM Network Management
C79000-G8976-C137-08
2.4 Factory Defaults and Protected Settings
Defaults
The OSM/ESM had default settings made in the factory (see 4.7.3Factory
Defaults). The user can query and modify these defaults with WBM, the CLI or
SNMP.
The screenshots of the WBM dialogs in Chapter 4 show the default settings. You
will find further default settings in the private MIB file (see Section 4.7.3).
Restore Memory Defaults and Restart
Using WBM or the CLI, a command is available with which it is also possible to
restore some of the factory defaults.
Apart from the protected settings, all the settings are restored to the factory
setting.
Protected Settings
The protected settings of the OSM/ESM are not modified when you restore the
factory defaults to avoid having to make settings again unnecessarily.
The protected settings are as follows:
IP address, subnet mask, default gateway, system name, system location, system
contact.
Restore Factory Defaults
Using WBM or the CLI, a command is available with which it is also possible to
restore the factory defaults. The factory defaults are also restored if you trigger a
RESET with the button on the front panel of the OSM/ESM, see /1/.
The protected settings are also reset!
If you trigger the function using the CLI or WBM, the device does not start
automatically. You will be prompted to start the device manually. Before you start
manually, you have the opportunity of reconfiguring the device. To be able to
communicate with the device later over the LAN, it is important to specify the IP
address.
Notice
If the device operates as standby master or standby slave, and the user configura-
tion of the linking signal lines does not match the default factory setting, make sure
that you disconnect the signal line(s) before starting the “Factory Default” function.