Web-Based Management (WBM)
4-23
Industrial Ethernet OSM/ESM Network Management
C79000-G8976-C137-08
4.8.2 OSM/ESM Standby Mask
Clicking the Standby Mask menu opens the window shown in Figure 4-13 .
Figure 4-13 OSM/ESM Standby Mask Window
With network management, you can define several standby ports when rings are
coupled redundantly, see Section 2.16. With a redundant configuration, you can
then interconnect several rings or networks redundantly.
In the standby mask, you specify which ports of the OSM/ESM will operate as
standby ports when working in the standby mode.
If there is no fault, only the standby ports of the standby master are active and
handle the data exchange. If the standby master or the link of one of the standby
ports of the master fails, all standby ports of the master are disabled and the
standby ports of the slave activated so that a functioning configuration is
established.
Please remember that the same ports on the standby master and on the standby
slave must be configured as the standby ports. If an optical port of the OSM ITP62
is used in the extended redundant configuration, it must have a hardware version