Configuration
34
Siemens Building Technologies
Fire Safety & Security Products 12.2008
NOTE
Descriptions of the Record icons in the Type column are as follows:
: Time-lapse (Time), :Alarm-In, : Motion, : Video Loss, : Text-In
NOTE
Channels that are not defined will use the setting values of the previous schedule item.
NOTE
When multiple events are detected at the same time from a specific channel, the DVR will record
event video with the high setting values if the ips, Quality, Resolution and Dwell values of events are
different from each other. However, the ips will be reset to the supported maximum value when the
ips, Quality, Resolution and Dwell are all set to the highest value. (Advanced Mode Only)
7. Highlight the box under the heading and press the button to delete the
recording settings.
Î You will be asked to confirm that you want to delete the settings.
8. Highlight Default… and press the
button.
Î The Default screen appears.
Fig. 30 Default (Advanced Mode) setup screen
Highlighting boxes under ips and pressing the
button allows you to set the
images per second for Time and Event recording. You can select from 1.00 to
25.00 (30.00 for NTSC) images per second.
Highlighting boxes under Quality and pressing the
button allows you to set
the recorded image quality for Time and Event recording. You can select
from: Very High, High, Standard and Low.
Highlighting boxes under Dwell and pressing the
button allows you to set
the length of time you would like to record for the associated event.
(Advanced Mode Only)
Î You can save your changes by highlighting OK and pressing the button.
Î Selecting Cancel exits the screen without saving the changes.