Machine Data, Modes and Traversing Programs IP 266
Positive offset:
Offset 32767.999 - |Software start limit switch|
Example: The drive is at the absolute position 50 mm. This position is to be offset
in succession by 400 mm, -200 mm and 0 mm.
Select mode 12.
Enter the coordinate value for the new actual position.
Start the mode with the "Start" function.
Repeat the sequence for each zero offset.
The coordinate system must "respond" as shown in Figure 5-23. You can con-
trol the response by viewing the actual-value displays.
Figure 5-23. Zero Offset in Mode 12
= Limit switches (software, hardware, emergency end switch)
s
0
-50
ZO 400 mm
ZO -200 mm
ZO 0 mm
0
350
-250
400
-200
Forward
N
A
H
A
REF H
A
N
A
50
Actual value
5-52
EWA 4NEB 812 6057-02