IP 266 Machine Data, Modes and Traversing Programs
Reference coordinate
The reference point is used to calibrate the axis. Its location can be specified via
the "Set/Approach to reference point" mode (see Section 5.3.5). The "reference
coordinate" machine data parameter is used to assign a value to this position.
The value must lie within the maximum range limits. When you define the
reference point coordinate, you also define the following coordinates:
coordinate basic origin
software limit switches
You can make absolute target specifications only in a system with a defined
reference point.
5.1.4 Speeds
The speeds specified in the machine data define the true speeds of the drive
system, and depend on
the motor rotational speed
the number of encoder pulses per revolution
the travel per encoder revolution
The absolute values for all speeds must be less than or equal to the maximum
speed. Input values must be in the range from 1 to 65,000. Depending on the
parameter assignments, the IP expects values in [mm/min], [deg/min] or
[0.1 inch/min].
Maximum speed
Under IP 266 control, the drive reaches the maximum speed with a setpoint of
±10 V
.
CAUTION :
The maximum speed must be computed from the technical specifications for
the complete drive system (motor, axis, encoder, and so on).
EWA 4NEB 812 6057-02