IP 266 Fundamentals of COM 266
Data area:
"Type" column: I = input field, O = output field
TypeField name
Module:
Meas.System:
Axis type:
Reference
speed 1:
O
Description
These fields are the same as those in the data area on page 1.
I The drive begins a reference point approach at this speed. Reference
speed 1 is the higher of the two speeds for the initial approach to
reference point, and must be less than or equal to the maximum speed.
Reference
speed 2:
I
Reference
direction:
I Defines the direction for the reference point approach. Use <F7> to
choose between 'forward' and 'reverse'.
Pulses/
revolution:
I
Travel/
revolution:
I The distance traversed per encoder revolution must be entered in this
field. The value must take into account all ratios between encoder and
axis.
PLC BCD coded: I When you select "yes" with <F7>, all coordinates transferred from the
PLC are interpreted in BCD code. The value range in BCD format is
restricted to +/-9999999 µm.
Polarity HW limit
switch:
I This field is used to indicate which edge of the limit switch or "External
Stop" signal is to be evaluated.
Specifies the number of pulses per encoder revolution (this information
can be obtained from the encoder's rating plate).
The IP 266 requires this speed for an exact approach to the reference
point. Reference speed 2 must be less than or equal to the maximum
speed and less than or equal to reference speed 1.
The "travel/pulses" resolution is computed from the values for "travel/revo-
lution" and "pulses/revolution"
EWA 4NEB 812 6057-02
6-35