Siemens KS7 Series Spezifikationen Seite 101

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 257
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 100
Print Mode CP 523
6.7.4 Form Feed (Job Number "5000
H
")
When prompted by the CPU, the CP 523 instructs the printer to execute a form feed. A form feed is
implemented by executing the number of line feeds configured (parameter block 5 "Page
format": lines per page). Headers, footers and page numbers are also printed depending on the
configuration.
Specify
Job number 5000
H
in word 0.
Example: Form feed
Start address 128 is set for the module.
A from feed is to be executed when flag 25.0 is set
* 5.2
STL FB 107 Explanation
NAME :FORMFEED
0005 :AN F 25.0
0006 :BEC
0007 :L KH 5000
0008 :T PW 128*
0009 :R F 25.0
000C :BE
The program is terminated if flag 25.0 is not set.
Load ACCUM 1 with the job number for "Form feed" and transfer
to the CP in word 0.
Job accepted by CP. Reset F 25.0
Block End
6.7.5 Line Feed (Job Number "6000
H
")
When prompted by the CPU, the CP 523 instructs the printer to execute a line feed.
Specify
Job number "6000
H
" in word 0.
Example: Line feed
The module is set to start address 128.
A line feed is to be executed when flag 25.1 is set.
* 5.2
STL FB 108 Explanation
NAME :LINEFEED
0005 :AN F 25.1
0006 :BEC
0007 :L KH 6000
0008 :T PW 128*
0009 :R F 25.1
000C :BE
The program is terminated if flag 25.1 is not set.
Load ACCUM 1 with the job number for ”Line feed” and transfer
to the CP in word 0.
Job accepted by CP. Reset F 25.1
Block End