CP 523 Technical Description
2.3 Serial Interface CP - Peripheral Device
The CP 523 is equipped with an RS-232-C (V.24) interface and a TTY interface. You can set the serial
interface parameters in two ways:
In the user program with job number 90
H
"Set interface parameters" parameter block
( 7.3.2).
The CP 523 copies the parameter setting data from the submodule into a RAM area on the CP
during startup. If the CPU transfers new parameter setting data to the CP during operation,
the CP continues with the new data.
In data block 1, parameter block 0, on the user submodule (Print mode 6.3.1,
Communications mode 7.3.1).
Data is transferred between the CP and the peripheral device in a 10-bit or 11-bit character frame.
Three data formats are available for each character frame.
10-Bit-character frame
1 start bit, 7 data bits, 2 stop bits (data format 3 in parameter block 0)
1 start bit, 7 data bits, 1 parity bit, 1 stop bit (data format 4 in parameter block 0)
1 start bit, 8 data bits, 1 stop bit (data format 5 in parameter block 0)
11-Bit-character frame
1 start bit, 7 data bits, 1 parity bit, 2 stop bits (data format 0 in parameter block 0)
1 start bit, 8 data bits, 1 parity bit, 1 stop bit (data format 1 in parameter block 0)
1 start bit, 8 data bits, 2 stop bits (data format 2 in parameter block 0)
Figure 2-3. 10-Bit Character Frame with 7 Data Bits, 1 Parity Bit and 1 Stop Bit
Bit no.:
1st example:
Character frame: 10-bit
Data format: 7 data bits (1 start bit, 7 data bits, 1 parity bit, 1 stop bit)
1 2 3 4 5 6 7 8 9 10
1
0
1
0
1 start
bit
1 pari-
ty bit
1 stop
bit
7 data bits
EWA 4NEB 811 6044-02a