Seitenansicht 229
CP 523 Summary
A Summary
A.1 Parameter Setting in Print Mode
Table A-1. Parameter Setting Data for Print Mode ( 6.3)
$ (24
H
)
(22
H
)
ASCII character
(01
H
to FF
H
)
ASCII character
(01
H
to FF
H
)
3
End-of-text character
Function character
1
(00
H
to FF
H
) · 25ms
(00
H
to FF
H
) · 25ms
(00
H
to FF
H
) · 25ms
0A
H
0.250 s
0A
H
0.250 s
A0
H
4 s
Waiting time after CR
LF
FF
XON character
XOFF character
ASCII character
(01
H
to 7F
H
)
ASCII character
(01
H
to 7F
H
)
FF
H
(no XON/XOFF
protocol)
FF
H
(no XON/XOFF
protocol)
2
Param.
Block
Value
Range
0
1
0
1
2
3
4
5
Baud rate 110 baud
200 baud
300 baud
600 baud
1200 baud
2400 baud
4800 baud
9600 baud
Description
Interface TTY
RS-232-C (V.24)
4
Default Value
on the CP 523
0
1
2
3
4
Parity even
odd
”mark”
”space”
no parity check
0
0
1
BUSY signal No
Yes
0
0
0
0
1
HW handshaking OFF
ON
0
0 1
2
3
4
5
6
7
8
Data format Parity:
11-bit character 7 data bits (yes)
frame 8 data bits (yes)
8 data bits (no)
10-bit character 7 data bits (no)
frame 7 data bits (yes)
8
data bits (no)
EWA 4NEB 811 6044-02a