CP 523 Print Mode
Additional information for "Print message text" (job numbers 0, 3 and 4)
The following can be additionally transferred to the CP 523 in words 2, 4 and 6 for "Print message
text" (job numbers 0, 3 and 4):
Values of variables
When printing the message text, the value transferred to the CP 523 is inserted instead of the
first spaceholder for variables configured in the message text.
Number of a message text to be inserted into a message text
When printing a message text, the message text with the number transferred to the CP 523 is
inserted in place of the spaceholder for message texts.
Table 6-19. Transferring Additional Information for "Print Message Text"
Meaning AssignmentWord
(Byte)
Value of the variables
or
number of the message text to be inserted
0000
H
to FFFF
H
(Dependent on the configured data format)
0000
H
to 0FFF
H
4
(4+5)
Value of the variables
or
number of the message text to be inserted
0000
H
to FFFF
H
(Dependent on the configured data format)
0000
H
to 0FFF
H
2
(2+3)
Value of the variables
or
number of the message text to be inserted
0000
H
to FFFF
H
(Dependent on the configured data format)
0000
H
to 0FFF
H
6
(6+7)
Setting the time of day (job number 10
H
)
Specify the variables in BCD in bytes 1 to 7. Specify weekdays as digits between 1 and 7 (1 = Sun-
day, 2 = Monday, ..., 7 = Saturday).
If an item of clock data is to remain unchanged, enter the value FFH in the relevant byte.
If a variable is outside the permissible range, the clock will not be set.
The CP flags the "Time of day/date error".
Table 6-20. Transferring Additional Information for "Print Message Text"
* Bit 7 = 1 in the case of the 12h clock
00
BCD
to 23
BCD
in the case of the 24h clock
01
BCD
to 12
BCD
in the case of the 12h clock a.m.
81
BCD
to 92
BCD
in the case of the 12h clock p.m.
Meaning AssignmentByte
Day 01
BCD
to 31
BCD
2
Month 01
BCD
to 12
BCD
3
Year 00
BCD
to 99
BCD
4
Hour
(Config. of the 12h clock or the 24h
clock
on
the memory submodule in DB 1)
5 *
Minute 00
BCD
to 59
BCD
6
Second 00
BCD
to 59
BCD
7
EWA 4NEB 811 6044-02a
6-39