Siemens KS7 Series Spezifikationen Seite 81

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 257
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 80
Print Mode CP 523
6.4.6 Spaceholders for Variables
The spaceholder is replaced by the variable at printout.
You must specify the variables in bytes 2 to 7 in the "Print message text" request:
Byte 2 and 3 : Value of the 1st variable (data format as configured)
Byte 4 and 5 : Value of the 2nd variable (data format as configured)
Byte 6 and 7 : Value of the 3rd variable (data format as configured)
The first spaceholder configured for variables in the message text is replaced by the variable 1, the
second by variable 2 and the third by variable 3.
Note:
If the message text contains more than three spaceholders for variables, they are not
interpreted as spaceholders but printed out as text.
If a spaceholder is wrongly configured, it is also treated as text and printed out.
When spaceholders are replaced by the appropriate values, the total length may be greater
than 136 characters.
You must specify the data format in which the variable has been transferred from the CPU as the
spaceholder.
Table 6-8. Data Formats for Variables
* The time is printed out in seconds ("s").
Number of
Printed Positions
Value RangeData Format
KM Constant: Bit pattern
KH Constant: Hexadecimal pattern
KC/KS Constant: Alphanumeric characters
KT Constant: Time base
KZ Constant: Count
KY Constant: Byte, byte
16 bits
0000
H
to FFFF
H
20
H
to 7F
H
/ 20
H
to 7F
H
1.0 to 999.3 *
0 to 999
0 to 255, 0 to 255
-32768 to+32767
KB Constant: Byte 0 to 255
KG Constant: Floating-point number
KG.
-1,7E38 to -1,4E-37
1,4E37 to 1,7E-38
KGa,b Constant: Floating-point number
KGa.b a Number
of characters to be printed ( 9)
b Decimal places ( 6)
-999 999 to 999 999
0.000001 to 9999999
KF Constant: Fixed-point number -32768 to+32767
16
4
2
4
3
7
3
6
Configurable
( 9)
13
Configurable
( 9)
KFa,b Constant: Fixed-point number
KFa.b a Number
of characters to be printed ( 9)
b Decimal places
6-26
EWA 4NEB 811 6044-02a
Seitenansicht 80
1 2 ... 76 77 78 79 80 81 82 83 84 85 86 ... 256 257

Kommentare zu diesen Handbüchern