00497GB-2009/R01
Availability, design and specifi cations are subject to change without notice. All rights reserved.
X024 - 32
www.asconumatics.eu
2005 - 2005 - 2012 - 15407-2 18 & 26mm Series
05 F ES 1 Z1 J L 000 00
Pressure Range
1 = 0.7 to 9 bar
3 = 0.2 to 2 bar
4 = 0.5 to 4 bar
Options
000 = Standard
12H = Without gauge
16N = Jumper on 14 end
16P = Jumper on 12 end
16W = Top facing gauge* (2005 series)
61Y = Extended gauge* (2005 series)
63D = 16W + 61Y* (2005 series)
* see note below
Further options on request
Wiring Option
J = Plug-in receptacle
Mounting 2005 2012-35
00 = Without base X X
01 = With sandwich speed control X X
Z0 =
Manifold block with side and bottom ports,
“Z-Board“,
used with EE regulator
X
Z1 =
Manifold block with side and bottom ports,
“Z-Board“ single actuated
XX
Z2 =
Manifold block with side and bottom ports,
“Z-Board“ double actuated
XX
Z5 = Z1 with speed control X X
Z6 = Z2 with speed control X X
R1 = Z1 with ribbon cable connector X X
R2 = Z2 with ribbon cable connector X X
R5 = Z5 with ribbon cable connector X X
R6 = Z6 with ribbon cable connector X X
Port Type of Bases
O = Without base
Q = G thread
K = Plug-in fittings
Note (2005 series):
Regulator gauges must be offset on alternating sta-
tions to prevent interference (see photo)
Odd numbered stations will use either standard (no
option) or top facing (“16W” option) gauges.
Even numbered stations will use either extended
standard (“61Y” option) or extended top facing
(“63D” option) gauges.
Port Size of Base 2005 2012 2035
1 = G 1/8 or valve w/o manifold X
2 = G 1/4 or valve w/o manifold X
3 = G 3/8 or valve w/o manifold X X
4 = G 1/2 or valve w/o manifold X
F = 6 mm push-in fitting X
H = 8 mm push-in fitting X X
K = 10 mm push-in fitting X
Regulator Type
ES = Single pressure to port 1
ED = Dual pressure to ports 3 and 5
EC =
Dual pressure with non-relieving checks (2012 and
2035 series)
EQ =
Dual pressure with relieving checks (2012 and 2035
series)
EE = Dual pressure to ports 4 and 2
ET = Two-pressure selector
Ribbon cable option must be used for manifold
assemblies that exceed 16 solenoids.
(7th and 8th digit of valve order code)
(please refer to explanations on page X021-25-60)
Series
05 =
2005 Series
12 =
2012 Series
35 =
2035 Series
I5 =
2005 Series ISO 15407-2 18mm
I6 =
2012 Series ISO 15407-2 26mm
Symbols
14
12
24
14
5
1
3
12
24
14
5
1
3
12
14 12
14
5
1
3
12
24
Single pressure
from a single supply
Dual pressure
from a single supply
Non-relieving:
taps downstream pressure if
upstream is exhausted
14
5
1
3
12
24
14
5
5
42
31
1
3
12
24
14
5
1
3
12
14 12
12
24
14
Relieving:
exhausts pressure in cylinder
if upstream pressure is
exhausted
External outlet regulator used
with jumper plate for single or
dual pressure
Two-pressure selector used
for multi-pressure applications
ES ED EC
(2012-2035)
ETEEEQ
(2012-2035)