00497GB-2009/R01
Availability, design and specifi cations are subject to change without notice. All rights reserved.
X024 - 32
www.asconumatics.eu
2005 - 2005 - 2012 - 15407-2 18 & 26mm Series
05 F ES 1 Z1 J L 000 00
Pressure Range
1 = 0.7 to 9 bar
3 = 0.2 to 2 bar
4 = 0.5 to 4 bar
Options
000 = Standard
12H = Without gauge
16N = Jumper on 14 end
16P = Jumper on 12 end
16W = Top facing gauge* (2005 series)
61Y = Extended gauge* (2005 series)
63D = 16W + 61Y* (2005 series)
* see note below
Further options on request
Wiring Option
J = Plug-in receptacle
Mounting 2005 2012-35
00 = Without base X X
01 = With sandwich speed control X X
Z0 =
Manifold block with side and bottom ports,
“Z-Board“,
used with EE regulator
X
Z1 =
Manifold block with side and bottom ports,
“Z-Board“ single actuated
XX
Z2 =
Manifold block with side and bottom ports,
“Z-Board“ double actuated
XX
Z5 = Z1 with speed control X X
Z6 = Z2 with speed control X X
R1 = Z1 with ribbon cable connector X X
R2 = Z2 with ribbon cable connector X X
R5 = Z5 with ribbon cable connector X X
R6 = Z6 with ribbon cable connector X X
Port Type of Bases
O = Without base
Q = G thread
K = Plug-in fittings
Note (2005 series):
Regulator gauges must be offset on alternating sta-
tions to prevent interference (see photo)
• Odd numbered stations will use either standard (no
option) or top facing (“16W” option) gauges.
• Even numbered stations will use either extended
standard (“61Y” option) or extended top facing
(“63D” option) gauges.
Port Size of Base 2005 2012 2035
1 = G 1/8 or valve w/o manifold X
2 = G 1/4 or valve w/o manifold X
3 = G 3/8 or valve w/o manifold X X
4 = G 1/2 or valve w/o manifold X
F = 6 mm push-in fitting X
H = 8 mm push-in fitting X X
K = 10 mm push-in fitting X
Regulator Type
ES = Single pressure to port 1
ED = Dual pressure to ports 3 and 5
EC =
Dual pressure with non-relieving checks (2012 and
2035 series)
EQ =
Dual pressure with relieving checks (2012 and 2035
series)
EE = Dual pressure to ports 4 and 2
ET = Two-pressure selector
Ribbon cable option must be used for manifold
assemblies that exceed 16 solenoids.
(7th and 8th digit of valve order code)
(please refer to explanations on page X021-25-60)
Series
05 =
2005 Series
12 =
2012 Series
35 =
2035 Series
I5 =
2005 Series ISO 15407-2 18mm
I6 =
2012 Series ISO 15407-2 26mm
Symbols
14
12
24
14
5
1
3
12
24
14
5
1
3
12
14 12
14
5
1
3
12
24
Single pressure
from a single supply
Dual pressure
from a single supply
Non-relieving:
taps downstream pressure if
upstream is exhausted
14
5
1
3
12
24
14
5
5
42
31
1
3
12
24
14
5
1
3
12
14 12
12
24
14
Relieving:
exhausts pressure in cylinder
if upstream pressure is
exhausted
External outlet regulator used
with jumper plate for single or
dual pressure
Two-pressure selector used
for multi-pressure applications
ES ED EC
(2012-2035)
ETEEEQ
(2012-2035)
2.b How to Order - Regulators