G3 Platform Distribution Options
The G3 platform is flexible to the point that there are a virtually infinite number of I/O distribution options using
the few basic G3 modules. The following basic rules should be followed in the configuration of your control
architecture.
Valve Side
• Up to a total of 32 valve solenoids can be driven in
a manifold assembly integrated into the Main Fieldbus
Island. This can be any number of single or double
solenoid valves with a total number of solenoids not to
exceed 32.
I/O Side Distribution
• A total of 16 modules can be integrated
into the network and controlled by the main fieldbus
communication module (Node)
• Modules include analog and digital I/O modules
providing addressing capacity for up to 256 Inputs /
544 Outputs (1200 bits) per node.
• Unique distribution system allows system efficiency
by allowing the same modules to be used in either
centralized or distributed applications
• Distribution options include Inputs only, Outputs only,
I/O only, valves with Inputs, valves with
Outputs and valves with I/O
• Configuration can include up to 16 of the
following modules:
- Digital I/O modules
- Backplane extension valve modules
- Analog I/O modules
Comm. Module
I/O Side
16 Modules can be
supported on this
side of the comm.
module
Main fieldbus
Comm. Module
Typical Main Fieldbus Island
Comm. Module
Valve Side
I/O Side
Kommentare zu diesen Handbüchern