Appendix E: Device Data Format
Siemens Energy & Automation, Inc. 125
General Status Word 4:
2
10 Bit Contents
2–15 Not Used
1 Trip circuit supervision active (Valid)
0 Trip circuit supervision active (Status)
Number of Last Fault 11 0…32767, 0 = no faults
Fault Date/Time (ms) 12 0…59999 (ms )
Fault Date/Time (h/m) 13 High byte: HH (0…23), Low byte: MM (0…59)
Fault Date/Time (m/d) 14 High byte: MM (1…12); Low byte: DD (1…31)
Fault Date/Time (y) 15 Year: YY (00…99)
Interrupted current:
Phase L1 (I/I
n
)
16 ms since fault (-1 = no occurance)
Interrupted current:
Phase L1 (I/I
n
)
17 Low word
Interrupted current:
Phase L1 (I/I
n
)
18 High word
Interrupted current:
Phase L2 (I/I
n
)
19 ms since fault (-1 = no occurance)
Interrupted current:
Phase L2 (I/I
n
)
20 Low word
Interrupted current:
Phase L2 (I/I
n
)
21 High word
Interrupted current:
Phase L3 (I/I
n
)
22 ms since fault (-1 = no occurance)
Interrupted current:
Phase L3 (I/I
n
)
23 Low word
Interrupted current:
Phase L3 (I/I
n
)
24 High word
Fault in the power system 25 ms since fault (-1 = no fault)
General Trip of Device 26 ms since fault (-1 = no occurance)
Thermal overload prot.:
Thermal warning
27 ms since fault (-1 = no occurance)
Thermal overload protection trip 28 ms since fault (-1 = no occurance)
O/C Fault Detection L1 only 29 ms since fault (-1 = no occurance)
O/C Fault Detection L1-E 30 ms since fault (-1 = no occurance)
O/C Fault Detection L2 only 31 ms since fault (-1 = no occurance)
O/C Fault Detection L2-E 32 ms since fault (-1 = no occurance)
O/C Fault Detection L1-L2 33 ms since fault (-1 = no occurance)
O/C Fault Detection L1-L2-E 34 ms since fault (-1 = no occurance)
O/C Fault Detection L3 35 ms since fault (-1 = no occurance)
O/C Fault Detection L3-E 36 ms since fault (-1 = no occurance)
O/C Fault Detection L1-L3 37 ms since fault (-1 = no occurance)
O/C Fault Detection L1-L3-E 38 ms since fault (-1 = no occurance)
O/C Fault Detection L2-L3 39 ms since fault (-1 = no occurance)
O/C Fault Detection L2-L3-E 40 ms since fault (-1 = no occurance)
O/C Fault Detection L1-L2-L3 41 ms since fault (-1 = no occurance)
O/C Fault Detection
L1-L2-L3-E
42 ms since fault (-1 = no occurance)
O/C Fault Detection E only 43 ms since fault (-1 = no occurance)
Real-Time Device Data Stored in PLC (7SJ600) (Continued)
Function Register Location in
PLC Block
1
Range or Contents