Appendix E: Device Data Format
132 Siemens Energy & Automation, Inc.
Restr. Curr. Of L3 at Trip
(average DC)
36 High word
Restr. Earth Flt.: Value D at Trip 37 ms since fault (-1 = no occurance)
Restr. Earth Flt.: Value D at Trip 38 Low word
Restr. Earth Flt.: Value D at Trip 39 High word
Restr. Earth Flt.: Value S at Trip 40 ms since fault (-1 = no occurance)
Restr. Earth Flt.: Value S at Trip 41 Low word
Restr. Earth Flt.: Value S at Trip 42 High word
Transformer Tank Prot.: Value at
Trip
43 ms since fault (-1 = no occurance)
Transformer Tank Prot.: Value at
Trip
44 Low word
Transformer Tank Prot.: Value at
Trip
45 High word
Fault in the power system 46 ms since fault (-1 = no fault)
General Trip of Device 47 ms since fault (-1 = no occurance)
Trip by thermal overload
protection 1
48 ms since fault (-1 = no occurance)
Trip by thermal overload
protection 2
49 ms since fault (-1 = no occurance)
Back-up Overcurrent: General Trip 50 ms since fault (-1 = no occurance)
External Trip 1: General Trip 51 ms since fault (-1 = no occurance)
External Trip 2: General Trip 52 ms since fault (-1 = no occurance)
Diff. Prot.: Blocked by
harmonics L1
53 ms since fault (-1 = no occurance)
Diff. Prot.: Blocked by
harmonics L2
54 ms since fault (-1 = no occurance)
Diff. Prot.: Blocked by
harmonics L3
55 ms since fault (-1 = no occurance)
Differential Protection: General Trip 56 ms since fault (-1 = no occurance)
Differential Protection: L1 57 ms since fault (-1 = no occurance)
Differential Protection: L2 58 ms since fault (-1 = no occurance)
Differential Protection: L3 59 ms since fault (-1 = no occurance)
Differential Protection: Trip by Idiff> 60 ms since fault (-1 = no occurance)
Differential Protection: Trip by
Idiff>>
61 ms since fault (-1 = no occurance)
Restr. Earth Flt.: General Trip 62 ms since fault (-1 = no occurance)
Transformer Tank Prot.: General
Trip
63 ms since fault (-1 = no occurance)
Reserved 64–67 For Future Expansion
1. This register location represents the sequential registers and their numbers within the device itself; as illustrated in Figure 5.1 in Chapter 5, the data
register numbers in the Modbus Master and the DTU3005 unit itself will vary from these register numbers.
2. Status information for each parameter is transmitted in two bits. The status bit indicates status (true = 1, false = 0) for the parameter and the valid bit indi-
cates that the device has sucessfully updated the value in the status bit (true = 1, false = 0).
Real-Time Device Data Stored in PLC (7UT513) (Continued)
Function Register Location in
PLC Block
1
Range or Contents