Additional Information CLV61x Dual Port (PROFINET IO)
8017978 / 2014-11-20 © SICK AG · Germany · All rights reserved · Subject to change without notice 16
Note: In the case of the CLV61x Dual Port, the input and output modules are added when the device is added.
These can be changed if required.
In addition, the I/O address must be selected.
The data must be handled consistently. Therefore, the I/O address for an S7-300/400 either must be
assigned so that it lies within its process image or the SFC 14/15 modules are used for consistent data
transmission.
The size of the process image can be viewed by double-clicking on the CPU in the hardware configuration
of S7. More details are available in the S7 documentation.
Example:
A process image size for the S7 CPU of 512 bytes is used here: