Additional Information CLV61x Dual Port (PROFINET IO)
8017978 / 2014-11-20 © SICK AG · Germany · All rights reserved · Subject to change without notice 39
7.3 Troubleshooting
This chapter provides some information on fault finding and rectification in the form of a condensed list.
Check the voltage supply Is the upper sensor LED lit blue?
Check the Ethernet connection Is LED P1 or LED P2 lit?
LED P1/P2: Green = connected, yellow = data exchange
Was the correct CLV61x Dual Port GSDML file used?
GSDML-V2.3-SICK-CLV61x_2Port-20141022.xml, or later.
Is the CLV61x Dual Port visible in the PROFINET with suitable name and IP?
Check the PN name via HW Config or the PST tool. See Chapters 7.10, 7.11, and 7.12
Read CLV61x Dual Port with SOPAS ET.
Check parameters such as PN name and IP address under "Network /Interfaces IOs / Profinet":
Is the mode selected suitable?
Handshake =
Function module or program necessary.
(Check E/A addresses and data length)
No Handshake =
Operation possible without programming
Is the triggering selected suitable?
Is the correct bit being used for fieldbus trigger? Bit 0 of Adr + 1 of "Ctrl Bits Out"
Can the CLV61x Dual Port read the desired code in Quickstart as a percentage value?
Check the GSCML configuration. If necessary, test by removing the GSDML configuration modules.