Additional Information CLV61x Dual Port (PROFINET IO)
8017978 / 2014-11-20 © SICK AG · Germany · All rights reserved · Subject to change without notice 7
3.1 Configuration of the CLV61x Dual Port via GSDML configuration
The CLV61x Dual Port can be permanently configured by modules in HW Config.
For this, the configuration modules are to be added after the Ctrl bits and the data channel. First, the module
"Start Remote Config" must be selected and the module "End Remote Config" must be added last.
Depending on the configuration task, one or more configuration modules can be added.
Through this GSDML configuration, the scope of the configuration for a typical task can be handled.
Very extensive or special configurations must be carried out per SOPAS ET directly in the CLV61x Dual
Port.
Important!
If the GSDML configuration is used, the CLV61x Dual Port is configured every time the PROFINET
is restarted. This cannot be suppressed in the ID sensor.
If in the meantime the CLV61x Dual Port was deconfigured locally (via USB or Ethernet Port 2111/2112)
using SOPAS ET, the existing configuration at PROFINET restart is lost as a result. In such a case, it may
be necessary to change or remove the GSDML configuration in the PLC in advance.
Example: CLV61x Dual Port bar code scanner:
Additional information is available in the GSDML documentation.