Additional Information CLV61x Dual Port (PROFINET IO)
8017978 / 2014-11-20 © SICK AG · Germany · All rights reserved · Subject to change without notice 35
GSDML configuration:
Note that GSDML configuration is optional and is sent to the CLV61x Dual Port every time PROFINET starts.
This overwrites the existing parameters in the CLV61x Dual Port.
Example:
• GSDML configuration must always begin with "01_Start_Remote Config":
For this, only Code 128 was activated and triggering via fieldbus bit selected.
• Secondly, reading configuration by the "11 Reading Config" module was selected:
For example, the scanning frequency can be adjusted here.
• As this is a simple application, the Handshake mode is switched off.
Note:
No Handshake must be carried out on the PLC and simple operation with a short data string can
take place.
If the SICK function module is to be used, the Handshake must be switched on.
• Additional configuration modules can be selected according to the application.
The process must always be completed with the "99_End_Remote Config" module.
• The HW Config must finally be saved and transferred to the PLC.