Additional Information CLV61x Dual Port (PROFINET IO)
8017978 / 2014-11-20 © SICK AG · Germany · All rights reserved · Subject to change without notice 6
2 Electrical connection
See operating instructions for "CLV61x Dual Port (PROFINET IO) Bar Code Scanner" (Document 8017842)
Additional information available at http://www.mysick.com/en/clv61x_dual_port
.
3 Configuration of the CLV61x Dual Port:
Configuration of the CLV61x Dual Port can be done in three different ways.
Configuration of the CLV61x Dual Port via GSDML configuration:
• Takes place directly in the PLC by addition of the GSDML configuration module.
• Allows automatic device replacement, even if the PN name is assigned automatically.
See Chapters 3.4 and 4.3.
• Only allows access to the parameters listed in the GSDML modules.
This is sufficient for standard applications and simple output formats.
Configuration of the CLV61x Dual Port via USB with SOPAS ET
• Carried out locally on the CLV61x Dual Port via SOPAS ET.
• When replacing devices, the CLV61x Dual Port must be reconfigured with SOPAS ET.
• Allows access only to all parameters of the device. This allows more complex output formats and
the like to be set.
Configuration of the CLV61x Dual Port via Ethernet with SOPAS ET
• Takes place via SOPAS ET over the PROFINET (Ethernet) network via TCP/IP (Port2111/2112).
The PC must be connected to the network.
• When replacing devices, the CLV61x Dual Port must be reconfigured with SOPAS ET.
• Allows access only to all parameters of the device. This allows more complex output formats and
the like to be set.