Siemens RS-485 Wartungshandbuch Seite 309

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 350
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 308
Installation instructions and notes on usage
D.4 Assembly instructions for SIMATIC NET PROFIBUS plastic fiber optics with BFOC connectors
PROFIBUS Network Manual
System Manual, Edition 04/2009, C79000-G8976-C124-03
309
5. Press the handles of the crimping pliers firmly together.
The connector body is joined to the core and the
crimping sleeve.
Note: The pliers can only be opened again when the
required pressure has been reached.
6. Open the crimping pliers and remove the core.
7. Push the anti-kink sleeve onto the connector body
as far as the limit stop.
8. Shorten the end of the fiber extending out of
the connector face to a length of 0.5 mm with scissors.
9. Repeat the same steps with the second core.
Notice: Do not insert the connector into the device socket
yet, the excess fiber extending out of the connector face
could damage the send and receive elements.