Devices for Special Applications
Heating, Cooling, Ventilation, Air-Conditioning
Room temperature controllers
7/7
Siemens ET G1 · 10/2008
■
Technical specifications
■
Selection and ordering data
i-system
DELTA
profil
DELTA
style
DELTA
ambiente
DELTA
millennium
Dimensions
•Height mm 55 65 68 65 65
•Width mm 55 65 68 65 65
•Depth mm 16 16 16 16 16
Type Description
UP 237
UP 252
UP 253
UP 254
UP 237, UP 252, UP 253, UP 254 room temperature controllers
• Integrated room temperature sensors
• Control can be set as a two-point control and/or continuous-
action control (P or PI algorithm), for heating only, for cooling
only, or for heating and cooling mode
• Comfort, standby, night, frost and heat protection operating
modes, which can be switched via KNX
• Presence pushbutton to locally switch between comfort and
standby mode and to extend comfort mode after operating
night mode
• Adjusting the room temperature setpoint offset for comfort
mode can be set via a rotary button on the controller and via the
KNX
• Basic setpoint of the room temperature for comfort mode
which can be set via the KNX
• Adjustable dead zone between the heating setpoint and
the cooling setpoint for comfort mode
• Two-level heating or cooling
• Output of the control variable(s) either as an ON/OFF
switch command or as a positioning command in
the range of 0 ... 100 %
• 5 LEDs to display the current operating mode and,
if necessary, the dew point alarm
• Mounting on a UP 110 or UP 114 bus coupling unit
IKE 250 IKE 250 room temperature controllers
• Integrated room temperature sensors
• Control can be set as a two-point control and/or continuous-
action control (P or PI algorithm), for heating only, for cooling
only, or for heating and cooling mode
• Operating modes comfort mode, standby mode, night mode
and frost or heat protection mode which can be switched via
KNX
• Two pushbuttons for local switching between comfort and
standby mode
• Two pushbuttons for adjusting the basic setpoint
• Basic setpoint of the room temperature for comfort mode which
can be set via the KNX
• Adjustable dead zone between the heating setpoint and
the cooling setpoint for comfort mode
• Output of the control variable(s) either as an ON/OFF
switch command or as a positioning command in the
range of 0 ... 100 %
• Red luminous bar for indicating the current setpoint
offsetting and the set operating mode
• Integrated bus coupling units
• 1 ground conductor and 1 ground terminal for the base
• Dimensions (H x W x D): 80 x 166 x 41 mm
Type Version DT Order No. Price
per PU
PU PS*/
P. uni t
PG Weight
per PU
approx.
Unit(s)Unit(s) kg
i-system
5WG1 237-2AB11
UP 237 UP 237 room temperature controllers
1)2)
• Titanium white
} 5WG1 237-2AB11
11 0220.048
• Carbon metallic B
5WG1 237-2AB21
11 0220.048
• Aluminum metallic A
5WG1 237-2AB31
11 0220.048
DELTA profil
5WG1 252-2AB13
UP 252 UP 252 room temperature controllers
1)2)
• Pearl gray B
5WG1 252-2AB03
11 0220.038
• Titanium white
} 5WG1 252-2AB13
11 0220.038
• Anthracite B
5WG1 252-2AB23
11 0220.038
•Silver A
5WG1 252-2AB73
11 0220.065
1)
The bus coupling unit must be ordered separately.
2)
The matching design frame must be ordered separately.