Devices for Special Applications
Safety
Intrusion
9/3
Siemens ET G1 · 10/2008
■
Technical specifications
■
Selection and ordering data
Type Description
N 345 N 345 presence-simulation modules
1)
• For recording switching, dimming and shutter/blind activities of
up to 32 channels and up to a total of 5000 actions over a
maximum period of 4 weeks (corresponds to 5 to 6 actions per
channel and day)
• Continuous recording or one-off recording of sample weeks
• Detection of public holidays during recording, which is taken
into account during simulation, with replay of the recorded
telegrams in the same order, but with time-definable random
deviation from the recording
• Return to the start of the simulation after 1 to 4 weeks
• Module-internal clock, which requires regular
synchronization by a master clock
• Electronics powered over bus voltage
• Integrated bus coupling units
• Bus connection over contact system to data rail
• Modular installation devices for mounting on
TH35 EN 60715 mounting rail
• Width 1 MW (1 MW = 18 mm)
N 266 N 266 detector group terminals
2)
• For the monitored connection of passive detectors
(e.g. magnetic contacts) and for the connection of floating
contacts in applications with increased safety demands
• 4 detector group inputs, each with one LED for status display
• Two 12 V outputs "walk test" and "setting/unsetting" for the
control of passive infrared and motion detectors
• Setting/unsetting of the detector group terminal over a
communication object
• With failure message in case of short circuit or interruption of a
signal line
• Electronics powered over an external power supply unit
for 12 V DC, max. 50 mA
• Monitoring of the external power supply
• Integrated bus coupling units
• Bus connection via bus terminal
• Modular installation devices for mounting on
TH35 EN 60715 mounting rail
• Width 4 MW (1 MW = 18 mm)
1)
The following devices can be used as a master clock or time source for synchronizing the module-internal real-time clock: a time switch
(e.g. 5WG1 372-5EY01) or an N 350E IP controller.
2)
The following (e.g.) is suitable as external power supply unit: LOGO!Power 6EP1 321-1SH01.
Type Version DT Order No. Price
per PU
PU PS*/
P. uni t
PG Weight
per PU
approx.
kg
5WG1 345-1AB01
N 345 N 345 presence-simulation modules u
Storage for 5000 actions
} 5WG1 345-1AB01
11 0300.100
5WG1 266-1AB01
N 266 N 266 detector group terminals
With 4 monitored inputs for passive detectors
B
5WG1 266-1AB01
11 0300.180
* You can order this quantity or a multiple thereof.
ET_G1_2009_en.book Seite 3 Freitag, 28. November 2008 9:50 09