Siemens SINUMERIK 802D sl Wartungshandbuch Seite 27

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 130
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 26
Setting-up
4.2 Limit stops
Manual Machine Plus Turning
Programming and Operating Manual, 06/2009, 6FC5398-6CP10-1BA0
27
Parameter
Parameter Description
ON The limit stop is activated.
OFF The limit stop is deactivated.
- X Negative absolute position of the limit stop of the X axis.
The axis stops automatically if:
The limit stop is active.
The specified axis traverses in the negative direction and reaches the absolute limit stop position.
+X Positive absolute position of the limit stop of the X axis.
The axis stops automatically if:
The limit stop is active.
The specified axis traverses in the positive direction and reaches the absolute limit stop position.
-Z Negative absolute position of the limit stop of the Z axis.
The axis stops automatically if:
The limit stop is active.
The specified axis traverses in the negative direction and reaches the absolute limit stop position.
+Z Positive absolute position of the limit stop of the Z axis.
The axis stops automatically if:
The limit stop is active.
The specified axis traverses in the positive direction and reaches the absolute limit stop position.
All of the limit stops are set in the following screen.
Figure 4-4 All limit stops set
Seitenansicht 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 129 130

Kommentare zu diesen Handbüchern

Keine Kommentare