Siemens v1.0 Wartungshandbuch Seite 118

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 202
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 117
Extended example
3.3 Test expanded program with program status
STEP 7 Basic V10.5
118 Getting Started, 12/2009, A5E02651459-01
3. In Network 1, modify the "ON_OFF_Switch" tag to "1".
The "ON_OFF_Switch" tag is set to the signal state "1". The current flows through the
normally open contact to the coils at the end of the network. The "ON" tag is set and the
example machine thereby switched on. The OFF tag remains reset to "0" and has no
further effect.
4. In Network 2, modify the "LS_1" tag to "1".
The "LS_1" tag is set to the signal state "1". This simulates that a bottle is detected by the
light barrier "LS1" at the start of the conveyor. The "chamber_ON_OFF" tag has the signal
state "0", because the heating chamber is switched off during the simulation.
Seitenansicht 117
1 2 ... 113 114 115 116 117 118 119 120 121 122 123 ... 201 202

Kommentare zu diesen Handbüchern

Keine Kommentare