Siemens v1.0 Wartungshandbuch Seite 61

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 202
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 60
Simple example
2.6 Create HMI screen
STEP 7 Basic V10.5
Getting Started, 12/2009, A5E02651459-01
61
3. Disable the alarms. These are not necessary for the example project.
Note
Alarms
If you enable the alarms via the HMI device wizard, you will be able to output the alarms
via the HMI device. The alarm windows created here will be created in the global screen
under "Screen management". Alarms are used, for example, to output warnings via the
HMI device when a limit is exceeded. Alarms can be supplemented by any additional
information, for example, to make it easier to localize faults in the system. A basic
distinction is made between user-defined alarms and system alarms:
User-defined alarms are used to monitor the machine process.
System alarms are imported into the project and contain status information of the HMI
device used.
Additional information on alarms is available in the information system of the TIA Portal.
Seitenansicht 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 201 202

Kommentare zu diesen Handbüchern

Keine Kommentare