Extended example
3.3 Test expanded program with program status
STEP 7 Basic V10.5
120 Getting Started, 12/2009, A5E02651459-01
6. In Network 2, modify the "LS_2" tag to "1".
In Network 2:
The "LS_2" tag is set to the signal state "1". This setting simulates that the bottle was
transported to the heating chamber and that the light barrier "LS2" was activated.
The current flow is rerouted to the input R1 of the "Set/reset flip-flop" instruction. The
conveyor_drive_ON_OFF tag is hereby reset and the conveyor stopped.
In Network 3:
The current flows through the contact of the main rung to the input S of the "Set/reset flip-
flop" instruction. The chamber_ON_OFF tag is hereby set to the signal state "1", and the
heating chamber is switched on.
In Network 5:
As soon as the heating chamber is switched on (Network 3), the LED tag is set to the
signal state "1" and the status light will be activated.