Example "Motion"
5.8 Start diagnostics view
STEP 7 Basic V10.5
Getting Started, 12/2009, A5E02651459-01
193
5. In Network 1, modify the "ON_OFF_Switch" tag to "1".
In network 1, the "ON_OFF_Switch" tag is set to the signal state "1". The current flows
through the normally open contact to the coils at the end of the network. The "ON" tag is
set and the example machine thereby switched on.
In network 4, the "MC_Power" instruction is executed and the motor axis of the conveyor
enabled.
6. Switch to the diagnostics of the technological object "Axis".
The enabling of the axis is displayed in the "Status" area of the diagnostics window.